Stainless Steel Flanged Slp Solenoid Valve

The Normally Closed Stainless Steel Flanged SLP Solenoid Valve is a high-performance pilot operated electric control valve designed for demanding industrial applications. Built with a durable stainless steel body, it ensures excellent resistance to corrosion and long service life. With a pressure rating up to 1.6MPa, this valve delivers stable performance and large flow capacity, making it ideal for water, air, gas, and steam systems. Its flanged connection provides easy installation, while factory-direct supply guarantees quality and cost-effectiveness.
Size:
Material:
Availability:
Quantity:
  • SLP

  • HONGJU

Nominal Diameter
Inch Diameter
Material
Length

(mm)
Height

(mm)
Pressure Resistance
DN15
G1/2”
304
105
135
0.05-1.6MPa
DN20
G3/4”
304
105
147
0.05-1.6MPa
DN25
G1”
304
137
155
0.05-1.6MPa
DN32
G1-1/4”
304
148
173
0.05-1.6MPa
DN40
G1-1/2”
304
155
180
0.05-1.6MPa
DN50
G2”
304
182
200
0.05-1.6MPa


Q1:About the Coil:
A:The solenoid valve is designed for short-term use. The coil will generate heat when energized. For standard models, continuous energization should be within 60 minutes.
For long-term operation, it is recommended to use the solenoid valve with an energy-saving module, allowing 24+ hours of continuous operation without overheating.
 
Q2:Working Principle:
A:Normally Closed (NC): Opens when energized, closes when power is off.
Normally Open (NO): Closes when energized, opens when power is off.(Requires at least 0.5 KG of pressure in the pipeline to open; will not open without sufficient pressure!)
 
Q3:Precautions:
A:When using with devices such as temperature controllers or level sensors, upper and lower limits must be set to allow the solenoid valve rest intervals.
Setting only one limit (upper or lower) will cause frequent valve operation, leading to coil burnout.
 
Q4:Installation:
A:There is an arrow on the valve body or base indicating the flow direction. Do not install it in reverse.
(This product is not suitable for media with large particles or impurities.)
If the medium is dirty, a filter must be installed.
There should be no pressure at the valve outlet. If pressure exists, a check valve must be installed.

Previous: 
Next: 
Zhejiang Hongju Automatic Control Valve Co., Ltd. is a valve manufacturing enterprise integrating R&D, design, production, sales, and after-sales service, with rich manufacturing experience.

Products

Quick Links

Contact Us
  Building 9 Unit 2 5th Floor South Zone China Safety Emergency Industry Park Kunpeng Street Haijing District Wenzhou
  market@hj-solenoidvalve.com
  export@hj-solenoidvalve.com
   +86-19015809390 / +86-15305879906 
  +8619016809390 / +8615305879906
Copyright © 2025 Zhejiang Hongju Automatic Control Valve Co., Ltd. All Rights Reserved.